Exam Details

  • Exam Code
    :3V0-21.21
  • Exam Name
    :Advanced Design VMware vSphere 7.x
  • Certification
    :VMware Certifications
  • Vendor
    :VMware
  • Total Questions
    :89 Q&As
  • Last Updated
    :Mar 22, 2025

VMware VMware Certifications 3V0-21.21 Questions & Answers

  • Question 61:

    Following a company merger, there are two data centers running vSphere environments. Both data centers are leveraging separate Layer 3 vMotion networks.

    Which requirement must be met in order to enable vMotion migration between these locations?

    A. The vMotion service must be configured on the Management VMkernel adapter

    B. A dedicated TCP/IP stack for vMotion with a dedicated gateway must be configured

    C. A stretched vMotion network must be configured between data centers

    D. Virtual machines must be powered off in order to migrate them between data centers

  • Question 62:

    An architect is designing a solution based on the following information:

    Each ESXi host has a single physical NIC with two 10 Gbps ports.

    There is a performance-based service-level agreement (SLA) that guarantees 15 Gbps bandwidth for

    production virtual machines at all times.

    There is no budget to purchase additional hardware.

    The hardware replacement SLA is based on a delivery agreement of two business days.

    Which recommendation for the configuration of vSphere High Availability (HA) should the architect include

    in the design?

    A. Configure vSphere HA Configure % based admission control Configure two isolation addresses Consider an OEM with NIC failure conditions in their Proactive HA plugin

    B. Configure vSphere HA Set das.IgnoreRedundantNetWarning to true Consider an OEM with NIC failure conditions in their Proactive HA plugin

    C. Configure vSphere HA Configure two existing data stores for heartbeat Consider an OEM with NIC failure conditions in their Proactive HA plugin

    D. Configure Proactive HA Automation Level: Automated Remediation: Maintenance mode for all failures Consider an OEM with NIC failure conditions in their Proactive HA plugin

  • Question 63:

    An architect is designing storage for a new vSphere environment to meet the following requirements:

    Asynchronous replication is required between two sites.

    The impact on the storage layer should not impact the performance of the compute layer.

    Each application tier will require different replication attributes.

    Virtual machine live migration across compute and storage must be supported.

    Virtual machine aware back up will be leveraged.

    Operational management overhead should be minimized.

    Operational automation should be supported.

    Which storage design recommendations would meet the requirements?

    A. Two new Fibre Channel storage arrays will be deployed, one at either site. Each application tier will be initially provisioned a new LUN. Data replication will be offloaded to the new arrays.

    B. Two new vSphere clusters enabled with vSAN will be deployed, one at either site. vSAN will be used to provide policy-based management for each application tier. vSphere Replication will be used to replicate the virtual machine data in an asynchronous configuration.

    C. Two new ISCSI storage arrays will be deployed, one at either site. Each application tier will be initially provisioned a new LUN. Data replication will be offloaded to the new arrays.

    D. Two new storage arrays will be deployed, one at either site. vSphere Volumes (vVOLs) will be used to provide policy-based management for each application tier. Data replication will be offloaded to the new arrays.

  • Question 64:

    An organization's data scientists are executing a plan to use machine learning (ML). They must have access to graphical processing unit (GPU) capabilities to execute their computational models when needed. The solutions architect needs to design a solution to ensure that GPUs can be shared by multiple virtual machines.

    Which two solutions should the architect recommend to meet these requirements? (Choose two.)

    A. NVIDIA vGPU

    B. AMD MxGPU

    C. vSphere DirectPath I/O

    D. vSGA

    E. vSphere Bitfusion

  • Question 65:

    An architect is designing a solution for an environment with two types of resource profiles that must be virtualized. The first type consists of Tier 1 virtual machines that are disk I/O intensive, but do NOT require high CPU or memory. The second type consists of Tier 2 virtual machines that require a lower CPU and memory allocation and have minimal disk I/O.

    Which design recommendation should the architect make for distributing the resource profiles?

    A. Separate the two resource profiles into two clusters. The Tier 1 cluster will have fast storage while the Tier 2 cluster will not.

    B. Run both resource profiles on the same cluster with the same host hardware platform.

    C. Separate the two resource profiles into two clusters. The Tier 2 cluster will have faster CPU and more memory while the Tier 1 cluster will have slower CPU and less memory but more disk space.

    D. Run both resource profiles on the same cluster with host hardware that has fast CPU, large amounts of memory, and the fastest storage platform.

  • Question 66:

    Application owners require support of a Microsoft Windows Server Failover Cluster (WSFC).

    Their current environment consists of the following components: vSphere 7.0 and vSAN 7.0 External array supporting NFS 3.0/4.1, Server Message Block (SMB) 2.1 10 GbE storage connectivity for all devices

    The solution architect is tasked with coming up with a solution to meet this requirement while utilizing their existing investments.

    Which two recommendations could the architect make? (Choose two.)

    A. Use vSAN native support for WSFC

    B. Use NFS 4.1 shares for quorum and shared disk

    C. Use raw device mapping (RDM)

    D. Use the SMB 2.1 protocol for sharing disks

    E. Run WSFC on vSAN iSCSI Target Service

  • Question 67:

    A Cloud Service Provider wants to introduce backup as a service for a customer's vSphere-based virtual machines.

    The following information is noted: All top-of-rack (ToR) switches are 10 GbE and fully populated The backup traffic must not impact existing services

    Which two recommendations should the architect make to help the customer incorporate the service? (Choose two.)

    A. Enable and tag traffic on the backup distributed port group

    B. Add a new two-port 10 GbE NIC per ESXi host

    C. Replace the existing NIC with a two-port 25 GbE NIC per ESXi host

    D. Match the Class of Service (CoS) and Differentiated Services Code Point (DSCP) values to the physical network

    E. Create a new virtual switch using the 1 GbE uplinks

  • Question 68:

    A customer has six hosts available in a cluster. When running at full capacity, all virtual machines can be run on two hosts.

    How many hosts can the customer place into maintenance mode at the same time while still providing N+2 resiliency to the cluster?

    A. Two

    B. Three

    C. One

    D. None

  • Question 69:

    An architect is designing a series of new vSphere environments for an organization. The environments will

    be deployed in their US-East and US-West region data centers. Each data center may have one or more

    dedicated vSphere environments. Only the vSphere environments within a data center will be configured

    with Enhanced Linked Mode. The Chief Technology Officer (CTO) has authorized the use of VMware

    vRealize Automation Cloud for automation. The build team creates standardized virtual machine images

    for various operating systems in Open Virtualization Format (OVF) and publishes the latest version on an

    as-needed basis to an internal HTTPS-accessible repository.

    The architect must design a content library topology that meets the following requirements:

    A localized content library must be available in each data center.

    Each content library must be updated when an image is updated and released by the build team.

    The cloud automation platform must be able to consume the latest approved content library images.

    It must leverage the existing build team processes.

    What should the architect recommend to meet the requirements?

    A. Work with the build team to create a local content library for each vSphere environment. Import the OVF images when new image are published to the repository.

    B. Create a local content library for the primary vSphere environment in each data center. Create a subscribed content library for each additional vSphere environment in each data center. Configure the content library to download content automatically.

    C. Work with the build team to automate a JSON-based manifest to the repository when changes occur in the repository. Create a subscribed content library for each vSphere environment. Configure the content library to download content when needed.

    D. Work with the build team to automate a JSON-based manifest to the repository when changes occur in the repository. Create a subscribed content library for each vSphere environment. Configure the content library to download content automatically.

  • Question 70:

    Which design decision must be included in a design to allow for the deployment of a minimum supported configuration of vCenter High Availability (HA)?

    A. A new subnet will be provisioned for vCenter HA services

    B. A vSphere cluster will consist of more than three nodes

    C. The deployed vCenter Server will be Tiny

    D. The vCenter HA network will support a latency of less than 50 ms

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only VMware exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your 3V0-21.21 exam preparations and VMware certification application, do not hesitate to visit our Vcedump.com to find your solutions here.