Exam Details

  • Exam Code
    :A4040-221
  • Exam Name
    :Assessment: AIX 7 Admininstration
  • Certification
    :CATE
  • Vendor
    :IBM
  • Total Questions
    :234 Q&As
  • Last Updated
    :Apr 03, 2025

IBM CATE A4040-221 Questions & Answers

  • Question 181:

    Two different administrators are asked to change the hostname of a system due to a misunderstanding The current hostname is set to misunderstanding. The current hostname is set to 'ozi'. The first administrator thinks the hostname should be set to 'kiwi' and he runs the command:

    # hostname kiwi He checks his work by running the hostname command again and he sees this output # hostname kiwi The second administrator thinks the hostname should be 'texan' and he runs the command: # uname -S texan He checks his work by running uname -n and sees the output # uname -n texan

    What will be the output of the hostname and uname -n command when the system reboots?

    A. The output of both commands will be 'kiwi' after reboot.

    B. The output of both commands will be 'texan' after reboot.

    C. The output of both commands will be 'ozi' after reboot.

    D. The output of the hostname command will be 'kiwi' and the output of the uname -n command will be texan".

  • Question 182:

    Which command will display the path status of MultiPath I/O (MHO) device hdisk1?

    A. Ispath-I hdisk1

    B. Ispv-L hdisk1

    C. chnlspath-I hdisk1

    D. Isdev-Cp hdisk1

  • Question 183:

    An administrator utilizes the parallel nature of dsh to streamline common tasks, but must serialize some to prevent network saturation. What dsh parameter will override the default behavior?

    A. The fanout parameter.

    B. The execute parameter.

    C. The node-options parameter

    D. The stream parameter

  • Question 184:

    A mirrored rootvg internal disk, hdisk1, has failed and must be replaced. The remaining mirrored disk, hdisk0, is intact and functioning normally. What is the correct sequence of actions?

    A. unmirrorvg rootvg hdisk1 reducevg roolvg hdisk1 rmdev -I hdisk1 -d physically replace hdisk1 cfgmgr extendvg rootvg hdisk1 mirroivg rootvg Run a bosboot on both disks

    B. rmdev-l hdisk1 -d

    physically replace hdisk1

    cfgmgr

    unmirrorvg rootvg hdisk1

    reducevg rootvg hdisk1

    extendvg rootvg hdisk1

    mirrorvg rootvg

    Run a bosboot on both disks

    C. unmirrorvg rootvg hdisk1 rmdev-I hdisk1 -d physically replace hdisk1 reducevg rootvg hdisk1 cfgmgr extendvg rootvg hdisk1 mirrorvg rootvg Run a bosboot on both disks

    D. unmirroivg rootvg hdisk1 reducevg rootvg hdisk1 rmdev -I hdisk1 -d physically replace hdisk1 cfgmgr extendvg rootvg hdisk1 Run a bosboot on both disks mirrorvg rootvg

  • Question 185:

    What infrastructure is necessary to support update installation to an existing IVM instance?

    A. Hardware Management Console

    B. Systems Director Management Console

    C. IBM Systems Director

    D. Network Install Manager

    E. Cluster Systems Manager

  • Question 186:

    What is the purpose of the virtual media repository on the VIO Server?

    A. To store resources for use by the NIM server

    B. To store backups of the VIO Server

    C. To store images for use by VIO Clients

    D. To store images for use by VIO Servers

  • Question 187:

    A system that will be re-installed has the following characteristics:

    If the following target_disk_data stanza is defined in the bosinst.data file used for the install, which disk will be installed with the operating system? target_disk_data: LOCATION = 0006bf1c3d817913 SIZE_MB = HDISKNAME = hdisk1

    A. hdisk0

    B. hdisk1

    C. hdisk2

    D. hdisk3

  • Question 188:

    What is a mandatory requirement to allow an AIX 7-based NIM Master to install clients over IPv6?

    A. The NIM Master must use static IPv6 addresses.

    B. The NIM Master must have both IPv4 and IPv6 connectivity.

    C. The NIM Master must be installed with the AIX Enterprise Edition license.

    D. The NIM Master must be running at least AIX 7.1 TLOO Service Pack3 or later.

  • Question 189:

    What TWO situations require a Systems Director Management Console (SDMC) instead of a Hardware

    Management Console (HMC)?

    (Select 2)

    A. Managing POWER5, POWER6 and POWER7 servers from one interface.

    B. Creating automation plans that perform specific functions on a given event.

    C. Implementing Active Memory Sharing (AMS).

    D. Utilizing Integrated Virtualization Manager (IVM) to manage Power Systems blades.

    E. Managing Power Blades and Power Systems standalone servers from one interface.

  • Question 190:

    In addition to an available DVD drive and 5GB disk space, what are the minimum server and LPAR requirements to install AIX 7.1 from DVD media?

    A. IBM PowerPC 970, POWER4, POWER5, POWER6 or POWER7 Server 512MB Memory

    B. IBM PowerPC 970, POWER4, POWER5, POWER6 or POWER7 Server 1024MB Memory

    C. IBM POWER4. POWER5. POWER6 or POWER7 Server 512MB Memory

    D. IBM POWER4, POWER5. POWER6 or POWER7 Server 1024MB Memory 3015

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only IBM exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your A4040-221 exam preparations and IBM certification application, do not hesitate to visit our Vcedump.com to find your solutions here.