Exam Details

  • Exam Code
    :E20-326
  • Exam Name
    :Symmetrix Solutions Design Exam
  • Certification
    :Technology Architect
  • Vendor
    :EMC
  • Total Questions
    :235 Q&As
  • Last Updated
    :Mar 09, 2025

EMC Technology Architect E20-326 Questions & Answers

  • Question 11:

    Refer to the exhibit.

    A customer has a Symmetrix VMAX storage array configured with FAST VP using three storage tiers. Policies are active for all storage groups on the array. The customer would like to increase the size of data movement requests. The current configuration of FAST is shown in the exhibit.

    Which parameter should be changed?

    A. Data Relocation Rate

    B. Max Simultaneous Moves

    C. Max Moves per Day

    D. Data Movement Mode

  • Question 12:

    Refer to the exhibit.

    You are considering potential configurations of a new storage system. You need to make decisions that consider different cost-benefit ratios. Which policy applied to the workload provides the best response time for the minimum expenditure?

    A. Moderate Skew

    B. Heavy Skew

    C. Low Skew

    D. Default Skew

  • Question 13:

    The SiRT feature is enabled on the RA in an SRDF/S configuration. When does the host receive the acknowledgement of a write?

    A. When I/O is written to the cache at the R2 site and acknowledgement is received by the R1 site from R2 site

    B. When I/O is written to R2 site cache but not acknowledged yet

    C. When I/O is written at R1 site cache and sent to the R2 site

    D. Immediately after the I/O is written to R1 cache

  • Question 14:

    A customer is planning a technology refresh. The proposed migration will make use of Open Replicator Hot Pull.

    Which Open Replicator Hot Pull feature allows them to minimize the possibility of data loss during the migration?

    A. Donor Update

    B. Symmetrix Differential Data Facility

    C. Protection Bitmap

    D. Symmetrix Track Table

  • Question 15:

    Refer to the exhibit.

    A customer has a Symmetrix VMAX storage array configured with FAST VP using three storage tiers. Policies are active for all storage groups on the array. The array has been in service for over 30 days. When using Unisphere for VMAX to check, the customer notices no active ingress and egress of extents for the EFD tier. The current configuration of FAST is shown in the exhibit.

    Which parameter should be changed?

    A. FAST VP Data Movement Mode

    B. Data Movement Mode

    C. Workload Analysis Period

    D. Min Initial Workload Period

  • Question 16:

    What is the most important advantage of implementing an ASM, Oracle 11g application on an existing Symmetrix array?

    A. Added volumes to an ASM instance would rebalance all existing Oracle objects automatically.

    B. Added new volumes to the ASM disk group will enable the DBA to issue an ASM rebalance command.

    C. Added volumes to the ASM disk group will automatically re-stripe the data across the target TimeFinder/Clone volumes.

    D. Added volumes to the ASM disk group will re-stripe the data across all target Oracle volumes.

  • Question 17:

    A customer plans to migrate existing AIX, HP-UX, and Windows hosts from a Symmetrix DMX-3 to a new VMAX array. You need performance data from the existing array to configure the layout of the new VMAX volume configuration.

    Which tools can be used to collect Symmetrix array performance data?

    A. ControlCenter Performance Manager STP Collector

    B. EMC Workload Generator STP Navigator

    C. Storage Configuration Advisor STP Collector

    D. ControlCenter Performance Manager SymmMerge

  • Question 18:

    A customer has implemented an Oracle application on a Symmetrix VMAX with a mix of Enterprise Flash Drives (EFD) and FC 15K drives. EFD are configured in RAID 5, and FC 15K drives are configured both in RAID 5 and RAID 1. In terms of IOPS activity, reads are predominant over writes. The customer decided to place a portion of the database in each tier.

    Which Oracle database object(s) is suitable for placing on the FC 15K RAID 1 drives?

    A. Redo log files

    B. Data files

    C. Index files

    D. Temp file

  • Question 19:

    Which database workload is suitable for an EFD configuration?

    A. Database objects with a random read workload

    B. Oracle online redo logs and archive log files

    C. DSS database with high sequential write activity

    D. Database objects with pure sequential workload

  • Question 20:

    Prior to creating the Symmetrix VMAX architecture for Microsoft SQL, you are given a Perfmon Log view containing data for the database LUN. The file contains read and write IOPS collected over the past week, at 3-minute intervals.

    Which method should be used to determine the correct IOPS target for calculating the appropriate number of RAID corrected spindles?

    A. 90th percentile

    B. 75th percentile

    C. Overall Peak

    D. Overall Average

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your E20-326 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.