Exam Details

  • Exam Code
    :H13-622
  • Exam Name
    :HCNP-Storage-CBDS (Constructing Big Data Storage)
  • Certification
    :Huawei Certifications
  • Vendor
    :Huawei
  • Total Questions
    :316 Q&As
  • Last Updated
    :Apr 14, 2025

Huawei Huawei Certifications H13-622 Questions & Answers

  • Question 141:

    Which of the following statements about the indicators on an N8500 clustered NAS system are correct? (Select two.)

    A. A power module runs properly if its indicator is steady red.

    B. The system is being started if the power indicator on the NAS service module blinks green.

    C. The data transmission rate is 4 Gbit/s if the port indicator on the NAS service 10GE interface card is steady blue.

    D. Data is being transmitted if the Active indicator of the management network port blinks orange.

  • Question 142:

    Which of the following is the correct sequence for powering on an OceanStor storage system?

    A. Connect the cabinet to the external power supply. -> Connect the PDUs to the external power supply. > Power on the storage nodes. -> Power on the switches. -> Power on the KVM. -> Power on the SMS modem.

    B. Connect the cabinet to the external power supply. -> Connect the PDUs to the external power supply. > Power on the switches. -> Power on the KVM. -> Power on the storage nodes. -> Power on the SMS modem.

    C. Connect the cabinet to the external power supply. -> Connect the PDUs to the external power supply. > Power on the KVM. -> Power on the storage nodes. -> Power on the switches. -> Power on the SMS modem.

    D. Connect the cabinet to the external power supply. -> Connect the PDUs to the external power supply. > Power on the KVM. -> Power on the storage nodes. -> Power on the SMS modem. -> Power on the switches.

  • Question 143:

    In a NetBackup-based N8500 file system backup network, all the nodes of the N8500 must be connected to both the NetBackup master server and media servers.

    A. True

    B. False

  • Question 144:

    Which of the following are necessary components of the NAS storage system architecture? (Select three.)

    A. Accessible storage array

    B. File system

    C. Interface provided for other devices to access the file system

    D. Fibre Channel switch

  • Question 145:

    Which of the following technologies is not suitable for the challenges brought by big data?

    A. FCSAN

    B. Object Storage

    C. Cluster

    D. 10GE or infiniband

  • Question 146:

    If an application server cannot access the storage resources of an N8500 storage system, which of the following operations can be performed for troubleshooting? (Select three.)

    A. Log in to the ISM to check alarms.

    B. Check the indicators on the storage system.

    C. Reinstall the ISM software.

    D. Restart the sharing service.

  • Question 147:

    The mirrored-stripe file system of the N8500 clustered NAS storage systems is ideal for scenarios that require high data security and read/write performance. Which of the following is the major technical feature of the mirrored-stripe file system?

    A. Data is striped and then mirrored, as in RAID 01.

    B. Data is mirrored and then striped, as in RAID 10.

    C. Data is stored in sequence on data disks that compose the file system.

    D. Data is stored in an interlaced manner on multiple data disks that compose the file system.

  • Question 148:

    The InfoLink function is enabled on an OceanStor 9000 storage system. If the node to which a client connects becomes faulty and a failover occurs, which of the following statements is incorrect?

    A. If the client accesses a shared directory through CIFS, the failover will cause disconnection and the client will need to reconnect to the storage system.

    B. If the client accesses a shared directory through NFS V4, the failover will cause disconnection and the client will need to reconnect to the storage system.

    C. If the client accesses a shared directory through NFS V4, the failover will not affect the connection.

    D. If the client accesses a shared directory through NFS V3, the failover will not affect the connection.

  • Question 149:

    A customer has purchased an N8500 clustered NAS storage system configured with ten 1 TB SAS disks and twelve 1 TB NL-SAS disks. Two RAID groups are planned. RAID group 1 is a RAID 5 consisting of nine SAS disks. RAID group 2 is a RAID 6 consisting of 11 NL-SAS disks. Two global hot spare disks are configured. What is the available capacity of the storage system?

    A. 20 TB

    B. 14 TB

    C. 15.6 TB

    D. 18.4 TB

  • Question 150:

    Which command is used to check whether the file system is in the online state for N8500 V200R001?

    A. storage fs list

    B. storage fs online

    C. storage fs status

    D. storage fs status show

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only Huawei exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your H13-622 exam preparations and Huawei certification application, do not hesitate to visit our Vcedump.com to find your solutions here.