A server has two power supply units (PSUs) in a redundant configuration. One PSU fails. A technician replaces the failed PSU, but the server does not return to redundant power mode.
What is the cause of this issue?
A. Power redundant option is disabled in the System Setup Utility.
B. Server has not been power cycled to bring the new PSU online
C. Both PSUs were not replaced at the same time
D. New PSU has a different wattage than the existing PSU
A technician is sent on-site to troubleshoot a server that produced an error message during the most recent POST but then completed the POST and booted to the operating system. The user cannot remember the specific error and no entry was made in the error log relating to this error.
How can the technician find out what the error message was?
A. Access the Lifecycle Controller and view the last boot cycle video capture entry.
B. Export the Server profile and analyze for any POST errors.
C. Reload the BIOS firmware.
D. Access the iDRAC and view the last boot cycle video capture entry
A technician needs to use the iDRAC GUI to roll back a diagnostics firmware revision on a server that was updated four weeks previously. However, the replaced version cannot be found in the Firmware Rollback section on the iDRAC GUI.
What could be the issue?
A. Diagnostics firmware revision is part of the Lifecycle Controller firmware so the Lifecycle Controller must be updated first
B. Rollback feature was not enabled in iDRAC Settings
C. Firmware can only be rolled back within a week of being replaced.
D. Diagnostics firmware is not supported in the Rollback feature.
A server is configured with a RAID 5 Virtual Disk across five hard disks and one spare disk. If a hard disk failure occurs within the RAID 5 virtual disk, the spare disk needs to be online as quickly as possible. It is acceptable for users to experience decreased performance during the rebuild procedure.
How should this requirement be met?
A. Enable Rebuild Priority
B. Increase Rebuild Rate
C. Change cache to Write Through
D. Select Fast Rebuild
A server has the following configuration: 5x 1 TB drives configured in a RAID 5 array 1x 1 TB as a global hot spare Persistent Hot Spare Slot enabled
A user adds one additional 2 TB drive to the existing array using RAID migration.
How much disk space is available to the operating system?
A. 5 TB
B. 6 TB
C. 7 TB
D. 8 TB
A technician is remotely installing ESXi 6.0 on a PowerEdge R640 in BIOS boot mode. The system has dual internal SD cards. After the OS is installed, the system reboots and shows an error screen with the following message: "No boot device found".
What should the technician do to resolve this issue?
A. Enable vFlash in iDRAC web GUI
B. Set the boot made from BIOS to UEFI
C. Reseat the SD cards and try to boot to them again
D. Change the Hard Disk Drive Sequence
A technician needs to connect a server to a network but the network switch has only two available network ports so only two network cables can be connected. The user needs as must bandwidth as possible for their workload so the two network cables need to connect to LOM1 and LOM2. The technician wants to satisfy the user requirements yet still be able to access the iDRAC.
What is the best way to configure the iDRAC?
A. Use a splitter cable in one of the network switch ports to connect the same cable to both LOM1 and LOM2 with the second network cable connecting to the iDRAC Dedicated NIC
B. Set up a dedicated NIC with LOM1 as the NIC selection
C. Use a splitter cable in one of the network switch ports to connect the same cable to both LOM1 and the iDRAC Dedicated NIC
D. Set up a shared LOM with LOM1 as the NIC selection
A technician has the ISO image of an OS that they need to install on a server in a remote location. They are already logged into the iDRAC. How should the technician install the OS?
A. Click Launch under the Virtual Console Preview, Select Next Boot, and choose Virtual CD/DVD/ISO
B. Click Launch under the Virtual Console Preview and then connect to Virtual Media
C. Click Launch under the Virtual Console Preview, reboot the server into F10, and start the Lifecycle Controller OS Deployment wizard
D. Click on Update and Rollback under Quick Launch Tasks
A technician needs to initially configure a server from a bare metal condition in the following area. Processor settings Disk configuration iDRAC network settings
The technician can only reboot the server once to achieve these tasks.
Where should the technician configure these settings?
A. PERC Configuration Utility and iDRAC Settings
B. PERC Configuration Utility only
C. System BIOS, iDRAC Settings, Device Settings
D. Device and PXE Settings
A technician needs to install several firmware updates on a server. The server cannot be rebooted until the customer performs a routine reboot.
What method should the technician use?
A. Upload all the firmware revisions using the Lifecycle Controller and then click Install Next Reboot.
B. Upload all the firmware revisions using the iDRAC and then select install Non-Reboot Only
C. Compress all the firmware revisions into a zipped file then use the iDRAC to upload and select Install Next Reboot
D. Upload all the firmware revisions using the iDRAC and then click Install Next Reboot.
Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your DES-4121 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.