In which VxRail models is the iDRAC NIC Selection Setting set to Dedicated?
A. E560, P570, V570, and S570
B. E560 and G560 only
C. P570, V570, and S570 only
D. P570, V570, S570 and G560
Which vSAN feature requires an All-Flash Cluster?
A. Erasure Coding
B. Storage Policy Based Management
C. vSAN Software Checksum
D. Data-at-Rest Encryption
A VxRail Stretched Cluster deployment will have E560F node. The Cluster must allow local protection with both erasure coding options at either site. What is the minimum node configuration?
A. 3+3 nodes
B. 4+4 nodes
C. 6+6 nodes
D. 8+8 nodes
What is the primary use of the VxRail PEQ Addendum?
A. Manually configuring VxRail Manager
B. Generating the NVT/FDC JSON configuration file
C. Deploying customer provided, non-Dell EMC network switches
D. Specifying Dell EMC-deployed switches and Stretched Clusters
Are some of the items contained in a VxRail As-Built Configuration report?
A. Security updates Support matrices Firewall Ports listing
B. Security updates Upgrade paths Firewall Ports listing
C. System configuration Support matrices Upgrade procedures
D. System configuration Firewall Ports listing Support matrices
What Role or Privilege does the VxRail Management User account need to have assigned within vCenter when connect ,o an External vCenter?
A. Readonly
B. No specific role
C. Administrator
D. HCIA
A system administrator attempts to use the VxRail REST API to obtain system health status for their VxRail environment. The system returns the following error code: 401. What should the administrator do to address this issue?
A. Provide vCenter credentials with sufficient rights.
B. Connect to vCenter GUI and try the command again
C. Wait five minutes and try the command again
D. Ensure that the VxRail Manager IP is correct
What is the purpose of the As-Built Configuration Generator?
A. Create the customer deliverable documentation of the Dell EMC product/solution implementation
B. Keep a record of all spare nodes, not yet added to a VxRail Cluster
C. Provide advanced control grouping for Stretched Clusters
D. Capture and generate the installation workflow for review in the event of a failed deployment
You receive the error "Invalid target datastore specified" while trying to deploy Doll EMC Secure Remote
Services.
What is the recommended course of action?
A. Rename the MARVIN-Virtual-SAN datastore to ESRS_VE.x86_64
B. Keep the SRS gateway powered for reference and redeploy manually
C. Delete the SRS gateway and redeploy using the manual method
D. Wait 10 minutes and try again
What components of a VxRail node must be assigned IP addresses?
A. ESXi host, vCenter, ESRS. and iDRAC
B. vSAN, vCenter, vRealize tog Insight, and vMotion
C. ESXi host, vSAN, vCenter, and ESRS
D. ESXi host, vSAN, vMotion, and iDRAC
Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your DES-6321 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.