NetApp NetApp Certifications NS0-520 Questions & Answers

  • Question 201:

    A customer that is using an AFF A220 has a problem with a host for a new FC LUN. Other LUNs on the same SVM are working properly. This LUN is not visible on the host. Which configuration does the customer need to verify in their solution?

    A. LUN mapping with igroup

    B. host HBA speed settings

    C. FC target port setting on NetApp node

    D. FC switch zoning

  • Question 202:

    A customer recently added two nodes with FC ports to a 4-node cluster.

    Which SVM configuration is needed before the customer creates LUNs on the new nodes?

    A. The FC service needs to be enabled on the data SVM.

    B. The existing LIFs need to be migrated to the new nodes.

    C. New FC LIFs need to be created on the cluster SVM.

    D. New FC LIFs need to be created on the new nodes.

  • Question 203:

    You are provisioning storage to an ESX host that uses iSCSI.

    According to NetApp best practice, which three actions accomplish this task? (Choose three.)

    A. Enable the iSCSI service.

    B. Bind the iSCSI ports to the software iSCSI adapter.

    C. Install Virtual Storage Console (VSC) for VMware.

    D. Enable BGP on the switch.

    E. Configure MTU 1500 on the switch.

  • Question 204:

    A customer is using both FC and NVMe in a cluster. The customer needs to do some work on AFF_1. Referring to the exhibit, what will happen?

    A. The NVMe namespaces on AFF_2 will be available after takeover of AFF_1.

    B. The FC LUNs that use cluster interconnect to access the LUNs on AFF_1 will be unavailable after failover.

    C. The FC LUNs on node AFF_2 will be unavailable after failover of AFF_1.

    D. The NVMe namespaces on AFF_1 will be unavailable after takeover by AFF_2.

  • Question 205:

    Which path selection policy is used by Windows Servers using NetApp LUNs that are greater than 2 TB?

    A. Least Queue Depth

    B. Round Robin

    C. Round Robin with Subset Policy

    D. Least Weighted Paths

  • Question 206:

    You configured a SAN host with a 4-node ONTAP 9.5 cluster that uses default settings. All paths are available from the host to the four nodes. You have a requirement to see only two paths to each LUN. One path is optimized and the other is non-optimized.

    In this scenario, which NetApp SAN feature supports this requirement?

    A. portsets

    B. SLM

    C. VLANs

    D. igroups

  • Question 207:

    An administrator has an ONTAP cluster with SVMs and LUNs as shown in the exhibit. Hosts attempting to connect to LUNs mapped from SVM "C" are unable to see their LUNs. The hosts are not configured to connect to any other SVM.

    Which action should be performed to restore multi-path connectivity to the LUNs in this scenario?

    A. Create LIFs on SVM "C" for host connectivity.

    B. Move the LUN to a different volume within SVM "C".

    C. Move the LUN to SVM "E" to restore connectivity.

    D. Move the LUN to SVM "A" to restore connectivity.

  • Question 208:

    You want to connect a NetApp AFF A700 to a 32 Gb FC switch. The ports need to connect at 32 Gb speed. In this scenario, which statement is correct?

    A. The AFF A700 includes FC ports natively on the controller.

    B. The AFF A700 includes an additional FC I/O module that is already populated in each controller.

    C. You need to purchase a two-port or four-port unified I/O module that enables FC and Ethernet connectivity.

    D. You need to purchase a two-port or four-port FC I/O module.

  • Question 209:

    You have a requirement to serve LUNs with under 200 microsecond latency using local server lass memory. You also are required to use a shared SAN.

    Using MAX Data as shown in the exhibit, which two LUN access protocols are supported with this solution? (Choose two.)

    A. iSCSI

    B. FCoE

    C. FC

    D. NVMe

  • Question 210:

    You have a 4 node cluster with an AFF A300 HA pair and a FAS8200 HA pair. You plan on using the default storage efficiency settings. With inline data compaction, you estimate that you can save 6% of storage space. AFF A300 LUNs that use under 5000 IOPS are moved to a FAS8200 using the lun move command.

    In this scenario, what happens to the data after the LUN is moved? (Choose two.)

    A. The new written data is not compacted.

    B. The new written data is compacted.

    C. The existing data is compacted.

    D. The existing data is not compacted.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only NetApp exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your NS0-520 exam preparations and NetApp certification application, do not hesitate to visit our Vcedump.com to find your solutions here.