Exam Details

  • Exam Code
    :E20-390
  • Exam Name
    :VNX Solutions Specialist Exam for Implementation Engineers
  • Certification
    :EMC Specialist
  • Vendor
    :EMC
  • Total Questions
    :412 Q&As
  • Last Updated
    :Mar 11, 2025

EMC EMC Specialist E20-390 Questions & Answers

  • Question 31:

    A company wants to use VNX Snapshots to create point in time views of their production LUNs. They discover that they cannot configure the snapshots they need.

    What might be causing this issue?

    A. LUNs are classic LUNs

    B. Pool that contains the LUNs is 90% full

    C. Reserved LUN Pool is not configured

    D. LUNs reside on the first four disks of the array

  • Question 32:

    A company experienced a network issue with one of its switches. This resulted in the users' inability to access their home directory on the VNX for File.

    Why did the VNX fail to bring up the services on the standby Data Mover since it is connected to a different network switch that was not affected?

    A. Network problems do not trigger Data Mover failover.

    B. The failover relationship was not set up correctly between the primary and secondary Data Movers.

    C. A hardware configuration mismatch prevented the secondary Data Mover to take over the responsibilities.

    D. The primary Data Mover could not notify the secondary Data Mover to take over the responsibilities.

  • Question 33:

    You have installed and implemented a VNX for File. After manual failover tests have been performed, a problem occurs on the primary Data Mover and the system becomes unavailable to the users. While reviewing the status in Unisphere, the Data Mover is reported as fault/panic and no failover occurs.

    What is the reason for this issue?

    A. Failover policy is set to manual

    B. Hardware configuration mismatch between the primary and standby Data Movers

    C. Primary Data Mover configuration is not visible to the standby Data Mover

    D. Failover will not occur when the Data Mover is in a panic state

  • Question 34:

    A customer has asked you to test the Data Mover failover functionality. Which method is recommended to verify Data Mover failover?

    A. Run the server_standby -activate command

    B. Remove the primary Data Mover blade from its slot

    C. Disconnect all Ethernet cables from the primary Data Mover

    D. Run the server_cpu -shutdown command

  • Question 35:

    A system administrator needs to change several CIFS parameters on a VNX for File system. How will the change affect the VNX system?

    A. Parameters will be applied per Data Mover and to all VDMs on the affected Data Mover

    B. Only the VDM where the parameter is set will be affected

    C. Only the CIFS server where the parameter is set will be affected

    D. Only the Data Movers and CIFS server created on the physical Data Mover will be affected

  • Question 36:

    A company is currently hosting an ISP service. For security reasons, they want to have different usermappers for each of their customers.

    Is this solution possible?

    A. Yes, but only for each Data Mover.

    B. Yes, by creating a unique usermapper on each VDM.

    C. No, but only for one primary usermapper per system.

    D. No, but only for one primary usermapper per site.

  • Question 37:

    A storage administrator is adding a third VNX system (VNX3) to a secondary site. The third system will be part of an active/active VNX IP replicating cluster. The administrator has set up the usermapper as a secondary usermapper (VNX2) pointing to the primary usermapper (VNX1).

    When will data on the secondary usermapper (VNX2) get updated if a new unmapped user is accessing the new VNX system (VNX3)?

    A. Not until the user accesses the CIFS server located on VNX2 B. As soon as the primary usermapper (VNX1) has generated an entry for the user

    C. At 0:00 AM every night when the primary usermapper (VNX1) updates all the secondary usermappers (VNX2/VNX3)

    D. As soon as an export of the database from the primary usermapper (VNX1) is imported to the VNX2 usermapper

  • Question 38:

    Which authentication method provides Kerberos-based user and data authentication, data integrity, and data privacy?

    A. Secure NFS

    B. UNIX security

    C. Authentication daemon

    D. Mixed mode

  • Question 39:

    What is recommended for creating a CIFS server on a VNX?

    A. Virtual Data Mover

    B. Physical Data Mover

    C. Remote Data Mover

    D. Standby Data Mover

  • Question 40:

    Which Microsoft applet is supported by VNX for creating CIFS shares?

    A. Computer Management Tool

    B. File Sharing

    C. File Management Tool

    D. Distributed File System

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only EMC exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your E20-390 exam preparations and EMC certification application, do not hesitate to visit our Vcedump.com to find your solutions here.