HP 600 Modular Disk System, HP extends and redefines direct-attached storage for BladeSystem servers, combining the simplicity and cost effectiveness of direct-attached storage without sacrificing flexibility or performance.
-
The HP 2000sa G2 Modular Smart Array is a 3Gb SAS direct attach
-
The HP 50 Modular Smart Array (MSA50) Enclosure is a 1U Serial Attach SCSI(SAS) disk drive storage enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives
Question 22:
HP Insight Remote Support can be configured to use an encrypted connection. To enable this feature, which TCP port needs to be allowed for outbound connection?
A. 22
B. 3389
C. 4253
D. 443
Correct Answer: D
http://h18004.www1.hp.com/products/servers/management/insight-remote-support/next- gen/ questionsanswers.html All information collected by Insight Remote Support is encrypted and digitally signed using an X.509 certificate prior to transport to HP. Data is sent to HP via secure HTTPS (SSLv3 or TLS) and is stored in a secure data facility in one of HP's corporate data centers.
Question 23:
Which Windows performance counters must be monitored to determine if a processor is overloaded?
A. Processor: % Processor Time and system: Processes
B. Processes: % Processor Time and system: Processor Queue length
C. Processor\% Processor Time and system\Processor Queue Length
D. Disk: Average Disk Queue Length and system: Processor Queue length
Correct Answer: C
http://technet.microsoft.com/en-us/library/cc938603.aspx Identify the processes that are running when Processor\% Processor Time and System\Processor Queue Length values are highest to determine.
Question 24:
A Microsoft Windows customer wants to add a file server presence to several existing and future remote sites. Redundancy, ease of management and hot swap storage growth capabilities beyond 32TB are required.
The solution must support iSCSI, FTP, and WebDAV for each site. Footprint and cost are concerns. What is the best solution?
A. X5000 running Windows Storage Server, D2700 enclosure
B. Four SL230p Gen8 nodes running Windows 2008 R2, SL6500 and ILO advanced licensing
C. Two DL360p Gen8 servers running Windows Storage Server and a D2600 enclosure
D. C7000, four BL460c Gen8 blades running Windows 2008 x64 and an MDS600
HP X5000 G2 Network Storage System At a Glance: Comprehensive, highly available Network Attached Storage appliance Two node, active/active mid-range NAS cluster and shared storage in a single system File and block storage capable - CIFS/SMB, NFS, iSCSI, HTTP, FTP, and WebDAV Advanced storage management features - File deduplication, File Classification Infrastructure, Hosted BranchCache, file screening, storage quotas, and storage reporting All inclusive software license Simple deployment and management All standard hardware and software pre-installed in system Power On to file serving in less than an hour 100% compatible with Windows IT infrastructure - Active Directory, Distributed File System (namespace and replication), Microsoft System Center and more Can be remotely managed for lights out data center or remote office locations Scalable and affordable Capable of supporting 10,000 plus users on a single system - dependent on storage configuration, LUN and RAID settings. User testing performed with Microsoft's File Server Capacity Tool. Up to 48TB of capacity inside the system, expands to over 100TB externally with HP D2000 Disk Enclosures File Deduplication feature can recover up to 40% of disk space File Classification Infrastructure feature provides insight into your data to help you manage it more effectively, reduce costs and mitigate risks based on the data's business value No need to buy additional hardware for anti-virus screening any Windows Server 2008 R2 compatible antivirus software runs right on the system Built on Windows Server 2008 R2 File Services Enables administrators to provide faster access to files while minimizing the effort required managing distributed data.
Question 25:
Which Windows performance counter can be used to check for a Smart Array disk bottleneck problem?
A. Logical Disk: Average Disk Queue Length
B. Physical Disk: Average Disk Queue length
C. Logical Disk: Average Disk Write Queue Length
D. Physical Disk: Average Disk Write Queue Length
Correct Answer: B
Question 26:
A customer is running several ESXi 5.0 servers and complains the workload is not properly balanced between the hosts even through the DRS cluster is configured. What should you verify?
A. EVC configured on the cluster level
B. Host monitoring configuration on the cluster level
C. Balloon driver activity ESXi hosts
D. Automation level configured on the cluster level
Correct Answer: D
Question 27:
To protect virtual running on multiple ESXi 5.0 hosts, a customer decides to configure a High Availability cluster. What are the requirements for this type of cluster?
A. The management network must be configured with the Fast Tolerant option enabled.
B. Enhanced VMotion compatibility mode and Storage DRS must be enabled on the cluster level.
C. Virtual machine must be stored on the datastore available from each member of the cluster.
D. The cluster must be configured using Host Profiles.
Correct Answer: C
Requirements for a VMware HA Cluster
Review this list before setting up a VMware HA cluster. For more information, follow the appropriate cross reference or see Creating a VMware HA Cluster.
All hosts must be licensed for VMware HA.
You need at least two hosts in the cluster.
All hosts need a unique host name.
All hosts need to be configured with static IP addresses. If you are using DHCP, you must ensure that the address for each host persists across reboots. All hosts must have access to the same management networks. There must be at least
one management network in common among all hosts and best practice is to have at least two. Management networks differ depending on the version of host you are using.
ESX hosts - service console network.
ESXi hosts earlier than version 4.0 - VMkernel network. ESXi hosts version 4.0 and later - VMkernel network with the Management Network checkbox enabled.
See Networking Best Practices.
To ensure that any virtual machine can run on any host in the cluster, all hosts should have access to the same virtual machine networks and datastores. Similarly, virtual machines must be located on shared, not local, storage otherwise they
cannot be failed over in the case of a host failure. For VM Monitoring to work, VMware tools must be installed. See VM and Application Monitoring. All hosts in a VMware HA cluster must have DNS configured so that the short host name
(without the domain suffix) of any host in the cluster can be resolved to the appropriate IP address from any other host in the cluster. Otherwise, the Configuring HA task could fail. If you add the host using the IP address, also enable reverse
DNS lookup (the IP address should be resolvable to the short host name).
Question 28:
Which HP SIM feature allows you to perform a Virtual Connect Profile movement from a failed server to a pace machine after the failure was discovered?
A. Insight Control virtual management functionality
Initiating VC Profile Failover using HP SIM Automatic Event Handling The VCEM custom tools enable an administrator to initiate a VC Profile Failover using automatic event handling. Any administrator with full permissions within HP SIM or VCEM can perform VC Profile Failover operations. The VCEM custom tools can be deleted from the HP SIM or VCEM installation with no impact to other operations.
Question 29:
Which Windows performance Monitor counter indicates that a network bottlenecks is occurring?
A. Network Interface: Output Queue Length
B. Network Interface: Current Bandwidth
C. Network Interface: Packets Sent/Sec
D. Network Interface: Packets Received/Sec
Correct Answer: A
Question 30:
A consultant is installing HP Power Protector on a VMware ESXi 4.1 server. What is needed for HP Power Protector to work correctly? (Select three)
A. Install HP Power Protector for Linux as an agent on the VMware ESXi 4.1 host.
B. Install HP Power Protector for VMware as a manager on the VMware ESXi 4.1 host.
C. Configure the firewall to block the ports used by HP Power Protector.
D. Install HP Power Protector for Linux as an agent on the VMware ESXi 4.1 VIMA/vMA.
E. The vSphere Client must be installed on a different machine for VMware ESXi 4.1 Server configuration
F. Configure the firewall to allow the ports used by the HP Power Protector.
Correct Answer: DEF
Verify the following applications are installed:
?VMware ESXi Server Machine ?VMware Infrastructure Management Assistant VIMA 1.0 or vSphere Management Assistant (vMA 5.X) installed as guest ?vSphere Client installed on a different machine for VMware ESXi Server configuration ?HPPP for Linux ?SSH client for installation and configuration ?SCP Client to upload packages to VIMA/vMA ?Tools installed on each Virtual Machine ?Firewall ports are open
Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only HP exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your HP0-S33 exam preparations and HP certification application, do not hesitate to visit our Vcedump.com to find your solutions here.