Exam Details

  • Exam Code
    :ISS-003
  • Exam Name
    :Intel Server Specialist Certification Exam
  • Certification
    :CompTIA Intel Server Specialist
  • Vendor
    :CompTIA
  • Total Questions
    :186 Q&As
  • Last Updated
    :Mar 25, 2025

CompTIA CompTIA Intel Server Specialist ISS-003 Questions & Answers

  • Question 171:

    A reseller would like to confirm that the chassis fans for an Intel Server Chassis are connected to the correct headers on the installed Intel Server Board. Which of the following documentation could be used to obtain this information?

    A. The Quick Start Guide for the Intel Server Board shows the required connections.

    B. The TPS for the Intel Server Chassis will contain details for the fans included in the specific chassis.

    C. The technical specifications of the Intel Server Board will show the proper connections.

    D. The TPS for the Intel Server Board will contain details for the fan headers for the specific server board.

  • Question 172:

    Which of the following are features of the Multi-Server Cloning option in the Intel Deployment Assistant? (Select ALL that apply).

    A. The servers must be connected via Ethernet cable to the management NIC.

    B. The BIOS and BMC settings cannot be cloned.

    C. The bootable image can be distributed via bootable USB key or across the network via a PXE server.

    D. Cloning is supported between any Intel dual socket server.

    E. Some parameters that should be unique with different servers can be modified.

  • Question 173:

    How would an Intel Server Specialist find the MAC addresses of the NICs (NIC1/NIC2/BMC (2 channels)/ Dedicated MGMT NIC) on the Intel Server Board S2600WT / S2600CW (based on the MAC address listed on the label)?

    A. NIC2 = MAC on label; NIC1 = MAC on label + 2; BMC (LAN CHANNEL 1) = MAC on label + 3; BMC (LAN CHANNEL 0) = MAC on label + 4; Dedicated Onboard NIC = MAC on label +5

    B. NIC1 = MAC on label; NIC2 = MAC on label + 1; BMC (LAN CHANNEL 0) = MAC on label + 2; BMC (LAN CHANNEL 1) = MAC on label + 3; Dedicated Onboard NIC = MAC on label +4

    C. NIC1 = MAC on label; NIC2 = MAC on label + 2; BMC (LAN CHANNEL 0) = MAC on label + 3; BMC (LAN CHANNEL 1) = MAC on label + 4; Dedicated Onboard NIC = MAC on label +5

    D. NIC1 = MAC on label; NIC2 = MAC on label + 11; BMC (LAN CHANNEL 0) = MAC on label + 12; BMC (LAN CHANNEL 1) = MAC on label + 13; Dedicated Onboard NIC = MAC on label +14

  • Question 174:

    An Intel Server Board S2600WT2 has been assembled and powered on; however, the status LED on the front panel blinks with an amber colour which means a non-critical alert has occurred. Which of the following might be the BEST way to find the reason for this alert?

    A. Listen to beep code and look for it in TPS.

    B. Look up ERROR MANAGER in the BIOS.

    C. View POST LED code and look for it in TPS.

    D. View the SEL log.

  • Question 175:

    Intel Deployment Assistant 7.1 can increase productivity during server build and validation by decreasing the time and effort required. Intel Deployment Assistant supports which of the following? (SelectALLthatapply).

    A. BMC/BIOS/Asset setup

    B. RAID logical volume configuration

    C. Read and dump raid Log

    D. Firmware update

    E. OS unattended installation; includes install all drivers automatically

    F. Read and dump SEL

    G. Power Node Manager configuration

  • Question 176:

    Which of the following can trigger an Intel Active System Console email alert from a server? (Select ALLthatapply).

    A. The server cooling fan(s) stop.

    B. The server chassis intrusion switch is enabled.

    C. A duplicate IP address is registered on the network.

    D. The Operating System service fails to start IASC.

    E. The HDD free space goes lower than 75%.

  • Question 177:

    From the following list, when might a customer find Intel Active System Console helpful?

    A. To identify the cause of a blinking status LED

    B. To update the BIOS, BMC, and FRU SDR for the server

    C. To ensure all drivers are up to date

    D. To analyses the operating system event logs

  • Question 178:

    Which of the following documents should be referred to for the CPU microcode version currently in use in the Intel server board?

    A. FRUSDR Release Notes

    B. BIOS Release Notes

    C. BMC Release Notes

    D. Technical product specification

    E. Supported processor list

  • Question 179:

    Which of the following BIOS setup pages should be entered in an Intel Server to configure the onboard SATA mode?

    A. Advanced PCH configuration

    B. Advanced-Processor Configuration

    C. Advanced-Disk Configuration

    D. Advanced-PCI Configuration

    E. Advanced-Mass Storage Controller Configuration

  • Question 180:

    Which of the following BIOS setup pages should be entered to disable the NUMA option?

    A. Advanced-Processor Configuration

    B. Advanced-PCI Configuration

    C. Server Management- BMC LAN Configuration

    D. Advanced-Memory Configuration-Memory RAS and Performance Configuration

    E. Security Page

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only CompTIA exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your ISS-003 exam preparations and CompTIA certification application, do not hesitate to visit our Vcedump.com to find your solutions here.