Exam Details

  • Exam Code
    :HPE0-J50
  • Exam Name
    :Integrating Protected HPE Storage Solutions
  • Certification
    :HP Certifications
  • Vendor
    :HP
  • Total Questions
    :68 Q&As
  • Last Updated
    :Mar 28, 2025

HP HP Certifications HPE0-J50 Questions & Answers

  • Question 51:

    A storage integrator is installing the HPE StoreVirtual Centralized Management Console (CMC) to manage a StoreVirtual VSA cluster. What is the proper procedure to install the console?

    A. Download the StoreVirtual CMC installer and start the installation from primary StoreVirtual VSA node.

    B. Download the CMC Appliance and deploy to a hypervisor not running StoreVirtual VSA nodes.

    C. Download the StoreVirtual CMC installer and run on the computer with a supported Linux operating system.

    D. Download the CMC Appliance and deploy to hypervisors running StoreVirtual VSA nodes.

  • Question 52:

    A customer with an HPE 3PAR 8200 unit has concerns about tracking missing updates and where to find the information on when upgrades were done in the past. With previous storage systems the customer ran out of storage before knowing that they needed to order more storage.

    What can the integrator do to help the customer with these concerns?

    A. Use the 3PAR Service Processor for Insplore event notification.

    B. Enable StoreFront Remote integration.

    C. Schedule SSMC Overview reports for the customer.

    D. Link the 3PAR Service Agreement ID to customer`s HPE passport account for storage reporting.

  • Question 53:

    A customer has HPE Data Protector and a StoreOnce VSA at a remote site that must replicate to the corporate data center StoreOnce backup device. What considerations must be taken into account to allow for Catalyst replication?

    A. Data Protector Catalyst replication will rehydrate the data on the StoreOnce VSA then write to the data center StoreOnce.

    B. Data Protector will write 2 backups: one to the StoreOnce VSA, the other to StoreOnce at the data center.

    C. Data Protector Catalyst replication requires gateways to both sites to use Object copy.

    D. Data Protector Catalyst replication is configured through the replication license on the StoreOnce VSA.

  • Question 54:

    A storage integrator is validating an HPE 3PAR StoreServ implementation. The integrator created a volume in the HPE 3PAR StoreServ Management Console (SSMC) and needs to verify read/write access from a Linux operating system. Which steps are part of the verification process? (Choose two.)

    A. Select Hosts under the Servers menu section, and click Create server.

    B. Select the volume in the Virtual Volumes section. and click Map Volume in the Actions menu.

    C. Select the host in the Servers section, and click Add permission in the Actions menu.

    D. Select the volume in the Virtual Volumes section, and click Export in the Actions menu.

    E. Select Hosts in the Block Persona menu section, and click Create host.

  • Question 55:

    Refer to the exhibit.

    A storage integrator is examining the configuration of an HPE 3PAR storage system using CLI. Which command can be used to display a list of common provisioning groups starting with substring R5 in the system?

    A. showcpg R5*

    B. cpg show | grep ^R5

    C. cpg | grep R5*

    D. cmore showcpg –I R5*

  • Question 56:

    A system engineer installed HPE Insight Remote Support for an HPE MSA 2042 storage system at a customer's site. The engineer wants to integrate the system in HPE Insight Online to monitor it remotely.

    Which information does the engineer need from the customer to do the integration, using the Insight Remote Support GUI with HPE Insight Online? (Choose two.)

    A. HPE Passport ID

    B. Product number of MSA 2042

    C. Service Agreement ID (SAID)

    D. HPE Passport password

    E. Serial number of MSA 2042

  • Question 57:

    A storage integrator installed an HPE 3PAR StoreServ system.

    For which default accounts will the storage integrator need to hand over changed passwords to the customer?

    A. 3parcust. 3paradm

    B. cpmaint, spmaint

    C. root, 3paradm

    D. root, console

  • Question 58:

    Your customer has a requirement to provide identification information to the PDU such as server name, UUID number, and IP address from their ProLiant-based storage products. Which PDU do you recommend to meet this requirement?

    A. HPE G2 Metered PDUs

    B. HPE Intelligent PDU

    C. HPE G2 Metered and Switched PDU

    D. HPE Standard Series G2 Basic PDU

  • Question 59:

    Refer to the exhibit.

    Which port can be used to connect the HPE MSA 2040 controller to hosts?

    A. 4

    B. 5

    C. 6

    D. 8

  • Question 60:

    Refer to the exhibit.

    The administrator has presented an HPE 3PAR StoreServer virtual volume to a server. A single virtual volume is seen as two different offline disks on a Windows 2012 R2 server. What must be done to correct the issue?

    A. Install HPE 3PAR DSM MPIO and reboot the server.

    B. Install the latest HBA driver and reboot the server.

    C. Install the MPIO feature and reboot the server.

    D. Install 3PAR host explorer and start service.

Tips on How to Prepare for the Exams

Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only HP exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your HPE0-J50 exam preparations and HP certification application, do not hesitate to visit our Vcedump.com to find your solutions here.