A Synergy integrator is unable to assign an HPE 3PAR Virtual Volume to a new server profile in HPE OneView. The Virtual Volume has been previously assigned to another profile.
Which setting in HPE OneView is preventing the integrator from assigning the volume to the new profile?
A. shared under storage pools
B. private under volumes
C. private under storage pools
D. shared under volumes
As part of a Synergy implementation, a Synergy integrator needs to create 100 networks in a Logical Interconnect Group (LIG) configuration. The network administrator for the end-of-row (EoR) switches provides a CSV file with the network that need to be created.
How should the Synergy integrator automate the creation of the 100 networks?
A. Upload the CSV file to the Composer and execute the Create Network wizard.
B. Use the HPE OneView PowerShell library to create the networks listed in the CSV file.
C. Start HPE SUT to migrate the CSV file to a Synergy configuration file and upload it to the composer.
D. Configure Image Streamer to automate the network configuration.
A Synergy integrator is creating a network that must be connected from the HPE Synergy Virtual Connect SE 40Gb F8 module to an Ethernet switch carrying 500 VLANs for the hypervisor cluster. Which network should the Synergy integrator select during network creation?
A. Ethernet Tunneled
B. Ethernet Channeled
C. Ethernet Tagged
D. Ethernet Untagged
A customer that uses a third-party storage array plants to set up Fibre Channel (FC) zones with the new HPE Synergy 12000 Frame. Which tool creates the FC zones in a Synergy solution?
A. storage page in the Synergy console
B. Virtual Connect module manager
C. corresponding SAN manager
D. Storage array command line utility
A customer has purchased 15 Synergy Frames with the following components:
150 HPE SY 480 compute modules
15 HPE Synergy D3940 storage modules with 40 disks each
6 Image Streamers
6 Virtual Connect SE 40Gb F8 modules
24 10Gb Interconnect Link Modules
How many frames can the configuration have for the Logical Enclosure?
A. 3 frames
B. 4 frames
C. 5 frames
D. 6 frames
In a 3-frame HPE Synergy environment, how should a Synergy integrator place the Image Streamer modules to allow for redundancy to all of the management connections?
A. one Image Streamer module in each Synergy frame (3 total)
B. one Image Streamer module in frame 2 and a second Image Streamer Module in frame 3 (2 total)
C. two Image Streamer modules in the frame 1 (2 total)
D. two Image Streamer modules in frame 2 and two Image Streamer Module in frame 3 (4 total)
A customer attempts to use an HPE Synergy Composer to discover an HPE BladeSystem c7000 enclosure. The customer is unable to migrate the HPE BladeSystem c7000 enclosure into the HPE Synergy Composer. What is preventing the customer from completing this task?
A. The migration must be initiated from the HPE OneView managing the HPE BladeSystem c7000 enclosure.
B. The HPE BladeSystem c7000 enclosure must be cabled to the Synergy management network.
C. The HPE OneView managing the HPE BladeSystem c700 enclosure must be upgraded to HPE OneView 3.0 before the Synergy Composer can migrate.
D. The Synergy Composer only supports HPE Synergy products.
A customer is using HPE Synergy Composer to manage the compute module and 3PAR volume attachments. The datastore attached to VMware servers has run out of space. What is the most efficient procedure the Synergy integrator should follow to extend the volume with minimum effect on the compute modules?
A. Set the volume to maintenance mode and increase the volume in 3PAR SSMC.
B. Create a snapshot and increase the capacity of the snapshot directly in the Synergy Composer.
C. Increase the capacity of the volume in the combined profile form.
D. Increase the capacity of the volume directly in the Synergy Composer.
Which utility compares currently running firmware with the upgrade firmware for the HPE Synergy 40Gb F8 Switch Module, which allows minimal downtime during the upgrade?
A. SMU
B. SUM
C. VCSU
D. ISSU
A customer has the following requirements for an HPE Synergy solution:
Data for the internal application needs to be stored in the frame.
Compute modules need to have access to a large database on an external storage array.
The Synergy infrastructure should be managed with HPE OneView.
How should a Synergy integrator configure the module installation?
A. two SAS Connection Modules into bays 1 and 2; two Synergy 40Gb F8 switch module into bays 3 and 4; two Brocade 16 Gb/12 Fibre Channel switches into bays 5 and 6
B. two SAS Connection Modules into bays 1 and 4; two HPE Synergy Virtual Connect SE 40Gb F8 modules into bays 3 and 6
C. two SAS Connection Modules into bays 1 and 2; two HPE Synergy Virtual Connect SE 40Gb F8 modules into bays 3 and 4
D. two SAS Connection Modules into bays 1 and 4; two Synergy 40Gb F8 switch module into bays 2 and 5; two Brocade 16 Gb/12 Fibre Channel switches into bays 3 and 6
Nowadays, the certification exams become more and more important and required by more and more enterprises when applying for a job. But how to prepare for the exam effectively? How to prepare for the exam in a short time with less efforts? How to get a ideal result and how to find the most reliable resources? Here on Vcedump.com, you will find all the answers. Vcedump.com provide not only HP exam questions, answers and explanations but also complete assistance on your exam preparation and certification application. If you are confused on your HPE0-S50 exam preparations and HP certification application, do not hesitate to visit our Vcedump.com to find your solutions here.